[물질전달] Liquid and Gaseous Diffusion Coefficient

 1  [물질전달] Liquid and Gaseous Diffusion Coefficient-1
 2  [물질전달] Liquid and Gaseous Diffusion Coefficient-2
 3  [물질전달] Liquid and Gaseous Diffusion Coefficient-3
 4  [물질전달] Liquid and Gaseous Diffusion Coefficient-4
 5  [물질전달] Liquid and Gaseous Diffusion Coefficient-5
 6  [물질전달] Liquid and Gaseous Diffusion Coefficient-6
 7  [물질전달] Liquid and Gaseous Diffusion Coefficient-7
 8  [물질전달] Liquid and Gaseous Diffusion Coefficient-8
 9  [물질전달] Liquid and Gaseous Diffusion Coefficient-9
 10  [물질전달] Liquid and Gaseous Diffusion Coefficient-10
 11  [물질전달] Liquid and Gaseous Diffusion Coefficient-11
 12  [물질전달] Liquid and Gaseous Diffusion Coefficient-12
 13  [물질전달] Liquid and Gaseous Diffusion Coefficient-13
※ 미리보기 이미지는 최대 20페이지까지만 지원합니다.
  • 분야
  • 등록일
  • 페이지/형식
  • 구매가격
  • 적립금
다운로드  네이버 로그인
소개글
[물질전달] Liquid and Gaseous Diffusion Coefficient에 대한 자료입니다.
목차
1. 서론
2. 실험이론

3. 실험방법

4. 실험결과 및 토론

5. 결론

6. 참고문헌

본문내용
7) 1440초 ~ 1680초

[그림9. 7구간의 시간대 전도도 그래프]

8) 1680초 ~ 1920초

[그림10. 8구간의 시간대 전도도 그래프]


- 각 그래프마다 구한 기울기들의 평균을 구한다. 그 평균값이 앞으로 확산계수 D를 계산하는데 쓰일 것이다.
8개의 그림에 나타나있는 기울기들의 평균을 구하면 4.708×10-8 (Ω-1 sec-1)이 된다.

- 2.실험이론 항목에 나와있는 식을 바탕으로 확산계수 D를 구한다.

, 에서



V = 1ℓ
x = 0.5 ㎝ = 0.005 m
d = 0.1㎝ = 0.001 m
N = 121
M = 2 mol/ℓ
CM = 0.41 Ω-1M-1
와 위에서 구한 기울기를 바탕으로 D를 구하면,


= 3.021 × 10-6 ℓm-1s-1
= 3.021 × 10-6 × (10-3 m3 ) m-1s-1
= 3.021 × 10-9 m2s-1

결국 D = 3.021 × 10-8 m2s-1 라는 결과를 얻었다.

- 이번에는 여기서 구한 확산계수와 그 문헌값을 비교해본다. 책에서 찾아본 물에서의 이온들의 확산계수는 다음 표와 같다.

Ions in water
확산계수
Ions in water
확산계수

1.96

2.08

9.31

2.03

1.03

1.46

1.33

2.05



5.30
[표2. 25℃에서의 확산계수, (10-9 m2s-1)]


참고문헌
- Momentum, Heat and Mass Transfer, C.O. Bennett, J.E.Myers 3rd edition.